Technique Specifications
Voltage input range: 200Vac~240Vac Protection of short circuit: Available
Rating input current: 0.79~0.66A Protection of open circuit: Available
Input frequency: 50Hz/60Hz Weight: 0.5 kg
Power factor: ≥0.95 Operating temperature range: -20℃~+40℃
THD ≤10% Max case temperature (TC): 85℃
Rating power: 150 W Dimming: No Dimming
Efficiency: 96.5% (Max) Dimension (L * W * H): 180*68*39mm
Voltage output range: 150Vdc~300Vdc Rating output current : 0.5A
Product Speciality Mounting Drawing
●Bright aluminium alloy case with perfect thermal efficiency
●Internally double protected by conformal coating and cooling colloid that ensures ballast work well in various environment
●Low noise, stable lumen output, no flicker, and multiple self-protection functions
●High efficiency
 
 
 
 
 
REMARK:
1、 Please read the instruction carefully prior to operating the ballast.
2、 No flicker with full and any range of power output.
3、 Protection of short:
① Output terminals short before starting: Pin<5W, action hour<5 seconds
② Output terminals short while starting: Pin<5W, action hour<5 seconds
③ Output terminals short while working: Pin<5W, action hour<5 seconds
4、 Protection of open:
① Output terminal open before starting: Pin<5W, action hour<5 seconds
② Output terminals open while starting: Pin<5W, action hour<5 seconds
③ Output terminals open while working: Pin<5W, action hour<5 seconds
5、 Hour from self-protection to automatic re-start: <5 seconds
6、 Insulation resistance: resistance between input and cabinet≥100MΩ under 500 Vdc test.
CAUTION:
1、 The output voltage of the ballast is possible up to 400V. It might be dangerous for people and equipments around. Please pay attention and keep other electric devices away from the ballast when it’s operating.
2、 Please ensure that output terminals are at least 500V rated.
3、 At least 1cm distance between LIVE and GND line to avoid short.
4、 Output terminals can not contact cabinet to avoid short.
5、 Ballast cabinet and fixture should be grounding.
6、 When removing the outer isolation of a cable, insert an extra isolation layer in its place.
7、 To ensure ventilation and raise cooling efficiency, please mount the ballast vertically.